J-MAG Series Electromagnetic Flow Meter
Product Description
Electromagnetic Flow meter is a high-precision, high-reliability flow meter. It is used to measure the volume flow of conductive liquids and slurry in closed pipes, and is widely used in industries such as iron and steel, electric power, petroleum, chemical industry, coal, metallurgy, mining, paper making, water supply and drainage, food, medicine and so on.
Features
- Not affected by fluid density, viscosity, temperature, pressure and
conductivity; - No moveable parts in the measuring tube, no pressure loss, and lower requirements for straight pipe sections.
- Two-way measurement system with three built-in totalizers, forward total, reverse total and difference total;
- Display forward and reverse flow, various outputs: current, pulse, digital communication , HART;
- Reasonable selection materials of liner and electrode, good corrosion resistance and wear resistance;
- Converter adopts excitation mode, has low power consumption, stable zero point and high accuracy.
- Using surface mount technology (SMT), with self-test and self-diagnosis alarm output, empty load detection alarm output, flow rate upper and lower limit alarm output, batch control and other functions
- Through infrared touch buttons, parameter setting is convenient and programming is reliable;
Technical Parameter
| Performance | Technical Parameter | Technical Parameter |
| Structure Type | Pipeline | Insertion type |
| Applicable Media | conductive liquid | conductive liquid |
| Accuracy | ±0.5 % | ±0.2%(customized) |
| Temperature Range | Ambient temp.(-10~60)℃ Medium temp temp..(-40~180)℃ |
ambient temp.(-10~60)℃ Medium temp temp..(-20~90)℃ |
| Power Suppl Supply | 220VAC/24VDC/3.6V | 220VAC/24VDC/3.6V |
| Working Pressuressure | 42Mpa (Maxpressure) |
4.0Mpa(max pr pressur essuree) |
| Responding Speed | ≤1S | ≤1S |
| Output Method | RS-485/HAR RS-485/HARTT;4-20mA analog output;pulse/fr pulse/frequency equency output | RS-485/HAR RS-485/HARTT;4-20mA analog output;pulse/fr pulse/frequency equency output |
| Pipe Material | Carbon steel ;Stainless tainless steel | Carbon steel ;Stainless tainless steel |
| Protection Class | IP65、IP68 | IP65、IP68 |
| Alarm point | Relay dry contact output, up to two channels | Relay dry contact output, up to two channels |
| Pipe Diameter Range | DN(3-3000) mm | DN100~DN3000 mm |
| Velocity Range | (0. 1~15)m/s | (0. 1~15)m/s |
| Turndown Ratio | 150:1 | 150:1 |
| Explosion-proof Grade | Exd[ia, Ga]II CT6 Gb | Exd[ia, Ga]II CT6 Gb |
| Process Connection | flange、thread、clamp | Ball valve |
| Electrical Interface | M20*1.5 | M20*1.5 |
| Display | Four-line LCD display | Four-line LCD display |