Residual chlorine, turbidity, suspended solids/sludge concentration, salinity, transparency, etc.
Residual chlorine/chlorine dioxide/ozone – Residual chlorine model: CL485/CLO485/O3-485
Turbidity (self-cleaning) NTU100; NTU200; NTU300
Turbidity High Temperature Type NTU2000-500
Suspended solids/sludge concentration (self-cleaning): SS100/MLSS100; SS200/MLSS200; SS300/MLSS300
UV-COD485;YLS485;LVZ485;TM485;SD485;SJD20A;YD485
Ammonia nitrogen, nitrate nitrogen, fluoride ions, hardness tester (calcium ions), chloride ions, sodium ions, potassium ions, lead ions, copper ions, cyanide ions, cadmium ions

Residual chlorine/chlorine dioxide/ozone - Residual chlorine model: CL485/CLO485/O3-485
Measurement range: 0-20 mg/L; Temperature range: 0-60°C; Power supply: 12-24VDC; Output signal: RS485; Liquid contact material: Quartz glass, ABS; Mounting interface: Lower PG13.5mm; Installation method: Flow-through; Applicable scenarios: Suitable for measuring residual chlorine, chlorine dioxide, and ozone in water.

Turbidity NTU100
Detection Method: Infrared optical method; Measurement Range: 0-10 NTU, 0-200 NTU, 0-4000 NTU, customizable; Resolution: 0.01 NTU, 0.1 NTU, 1 NTU; Temperature Range: -10-50°C; Operating Water Depth: IP68, 10m Max; Power Supply: 12-24VDC; Output Signal: RS485, 4-20mA; Mounting Thread: NPT3/4; Installation Method: Submersible; Material: 304 Stainless Steel, POM, Quartz Glass; Dimensions: Length: 200mm, Diameter: 48mm; Response Time: T90, <30s; Applicable Scenarios: Sewage, Surface Water, Tap Water, Swimming Pools, etc.

Turbidity NTU200
Detection Method: Infrared optical method; Measurement Range: 0-10 NTU, 0-200 NTU, 0-4000 NTU, customizable; Resolution: 0.01 NTU, 0.1 NTU, 1 NTU; Temperature Range: -10-50°C; Power Supply: 12-24VDC; Output Signal: RS485, 4-20mA; Installation Method: Flow-through, quick-connect fitting with 6mm outer diameter; Material: 304 stainless steel, POM, quartz glass, acrylic; Response Time: T90 < 30s; Applicable Scenarios: Sewage, surface water, tap water, swimming pools, etc.

Turbidity Self Cleaning TNU300
Detection Method: Infrared optical method; Cleaning Method: Automatic scraping; Measuring Range: 0-100NTU, 0-400NTU, 0-4000NTU, customizable; Resolution: 0.01NTU, 0.01NTU, 1NTU; Temperature Range: -10-50°C; Operating Water Depth: IP68, 10mMax; Power Supply: 12-24VDC; Output Signal: RS485, 4-20mA; Mounting Thread: NPT3/4; Material: 304 Stainless Steel, POM, Quartz Glass; Dimensions: Length: 200mm, Diameter: 48mm; Response Time: T90 < 30s; Applicable Scenarios: Sewage, surface water, swimming pools, aquaculture, sewage pipe networks, etc.

Turbidity High Temperature Type TNU2000-500
Detection Method: Infrared optical method; Measurement Range: 0-100 NTU, 0-2400 NTU, 0-4000 NTU, customizable; Resolution: 0.01 NTU, 0.01 NTU, 1 NTU; Temperature Range: 0-180°C; Power Supply: 12-24VDC; Output Signal: RS485, 4-20mA; Installation Method: Flow-through/Submersible (customizable); Material: 304 stainless steel, PTFE, quartz glass; Response Time: T90, <30s; Electrode Withstand Voltage: 0.3 MPa, 0.6 MPa; Applicable Scenarios: Chemical industry, wastewater treatment, brewing processes, etc.

Suspended Solids/Sludge Concentration SS100/MLSS100
Detection Method: Infrared optical method; Measurement Range: 0-100mg/L, 0-1000mg/L, 0-50000mg/L, customizable; Resolution: 0.01mg, 1mg, 1mg; Temperature Range: -10-50°C; Operating Water Depth: IP68, 10mMax; Power Supply: 12-24VDC; Output Signal: RS485, 4-20mA; Mounting Thread: NPT3/4; Installation Method: Submersible; Material: 304, POM, Quartz Glass; Dimensions: Length: 200mm, Diameter: 48mm; Response Time: T90, <30s; Applicable Scenarios: Water treatment, surface water, sewage pipe networks, etc.

Suspended Solids/Sludge Concentration SS200/MLSS200
Detection Method: Infrared optical method; Measurement Range: 0-10mg/L, 0-1000mg/L, 0-20g/L, customizable; Resolution: 0.01mg, 1mg, 1mg; Temperature Range: -10-50°C; Operating Water Depth: IP68, 10mMax; Power Supply: 12-24VDC; Output Signal: RS485, 4-20mA; Installation Method: Flow-through, quick-connect 6mm outer diameter; Material: 304 stainless steel, POM, quartz glass, acrylic; Response Time: T90, <30s; Applicable Scenarios: Sewage, surface water, tap water, swimming pools, etc.

Self-Cleaning-Suspended Solids/Sludge Concentration SS300/MLSS300
Detection Method: Infrared optical method; Cleaning Method: Automatic scraping; Measurement Range: 0-100mg/L, 0-1000mg/L, 0-50000mg/L, customizable; Resolution: 0.01mg, 1mg, 1mg; Temperature Range: -10-50°C; Operating Water Depth: IP68, 10mMax; Power Supply: 12-24VDC; Output Signal: RS485, 4-20mA; Mounting Thread: NPT3/4; Material: 304, POM, Quartz Glass; Dimensions: Length: 200mm, Diameter: 48mm; Response Time: T90, <30s; Applicable Scenarios: Sewage, surface water, swimming pools, aquaculture, sewage pipe networks, etc.

UV-COD485
Measurement range: 0-300mg/L, 0-1000mg/L, customizable; Temperature range: 0-60°C; Power supply: 12-24VDC; Output signal: RS485; Wettable materials: 304 stainless steel, PP, quartz glass; Mounting interface: NPT3/4; Operating water depth: IP68, 10m Max; Applicable scenarios: wastewater, surface water, swimming pools, aquaculture, sewage pipe networks, etc.

Chlorophyll YLS485
Detection method: Fluorescence method; Measurement range: 0.15-400ug/L; Resolution: 0.01ug; Temperature range: -10-50°C; Operating water depth: IP68, 10m max; Power supply: 12-24VDC; Output signal: RS485; Material: 304 stainless steel, PP, quartz glass; Dimensions: Length: 200mm, Diameter: 48mm; Response time: T90, <30s

Blue-green algae LVZ485
Detection method: Fluorescence method; Measurement range: 0.15-100ug/L; Resolution: 0.01ug; Temperature range: -10-50°C; Operating water depth: IP68, 10m max; Power supply: 12-24VDC; Output signal: RS485; Material: 304 stainless steel, PP, quartz glass; Dimensions: Length: 200mm, Diameter: 48mm; Response time: T90, <30s

Transparency TM485
Detection method: Optical; Measurement range: 2-200cm; Resolution: 0.01cm; Temperature range: -10-50°C; Operating water depth: IP68, 10m Max; Power supply: 12-24VDC; Output signal: RS485; Material: 304 stainless steel, PP, quartz glass; Dimensions: Length: 200mm, Diameter: 48mm; Response time: T90, <30s

Colorimetric SD485
Detection method: Optical; Measurement range: 1-100; Resolution: 0.01; Temperature range: -10-50°C; Operating water depth: IP68, 10m Max; Power: 12-24VDC; Output signal: RS485; Material: 304 stainless steel, PP, quartz glass; Dimensions: Length: 200mm, Diameter: 48mm; Response time: T90, <30s

Acid/Base Concentration Meter SJD20A
Installation Method: Flow-through; Measuring Range: 0-10% (HCl), 0-15% (NaOH); Resolution: 0.01%; Temperature Compensation Type: NTC2252, NTC10K, PT1000, PT100; Temperature Range: -10-80°C; Material: Hurricane, Quartz Glass; Mounting Interface: 8mm Quick-connect

Salinity YD485
Detection Method: Graphite two-electrode or four-electrode; Measurement Range: 0-200ppt; Temperature Range: -10-50°C; Operating Water Depth: IP68, 10m Max; Power Supply: 12-24VDC; Output Signal: RS485; Material: PPS, Graphite; Mounting Thread: Top and Bottom NPT3/4; Dimensions: Length: 140mm, Diameter: 31mm; Response Time: T90, <30s

Ammonia nitrogen, nitrate nitrogen, fluoride ions, hardness tester (calcium ions), chloride ions, sodium ions, potassium ions, lead ions, copper ions, cyanide ions, cadmium ions LZ485-XX
Detection Method: Ion electrode method; Measurement Range: Ammonia nitrogen 0-1000mg/L, Nitrogen nitrogen: 0-1000mg/L, Fluoride ions: 0-100mg/L, Hardness tester (calcium ions): 0-1000mg/L, Chloride ions: 0-1000mg/L, Sodium ions: 0-100mg/L, Potassium ions: 0-1000mg/L, Lead ions: 0-1000mg/L, Copper ions: 0-100mg/L, Cyanide ions: 0-200mg/L, Cadmium ions: 0-1000mg/L; Temperature Range: 0-50°C; Operating Water Depth: IP68, 10m Max; Power Supply: 12-24VDC; Output Signal: RS485; Material: ABS; Mounting Thread: Top and bottom NPT3/4; Dimensions: Dimensions: (Length: 250mm, Diameter: 37mm, Weight: 0.5kg); Response Time: T90, <30s